Version 02.00, November 2014
Rohde & Schwarz R&S
®
BTC Broadcast Test Center 23
Digital modulation systems
At least one I/Q baseband generator (R&S
®
BTC-B1 option) must be installed. If two I/Q baseband generators are installed
(R&S
®
BTC-B1 option and R&S
®
BTC-B2 option) and two signals of the same standard (e.g. DVB-T/DVB-H) are to be output
simultaneously, two corresponding software options must also be installed (in this case R&S
®
BTC-K501). If only one R&S
®
BTC-K501
is installed and DVB-T/DVB-H is selected in one I/Q baseband generator, the other I/Q baseband generator is disabled for
DVB-T/DVB-H. However, a software option is not tied to a specific I/Q baseband generator.
The specified data applies together with the parameters of the respective standard. The entire frequency range, the filter parameters
and symbol rates can be set by the user.
Terrestrial standards
DVB-T2 (R&S
®
BTC-K516 option)
DVB-T2
in line with EN 302755 and TS 102773
v1.1.1, v1.2.1
10
and v1.3.1
11
, incl. Annex I
single PLP and multi PLP
v1.1.1, v1.2.1
10
T2-Base single profile transmission
v1.3.1
11
T2-Lite single profile transmission
v1.3.1
11
in line with Annex I
Input
transport stream
interface
ASI
format
T2-MI (single PLP and multi PLP) or
MPEG-2 TS (single PLP only)
T2-MI
interface
on/off
PID filter
settable
12
SID filter
settable
12
analyzer
T2 specification check and logging
Modulation
modulation
COFDM
PLP number
1 (single PLP) to 20 (multi PLP)
single PLP
T2-MI interface
off
PLP number
1
single PLP and multi PLP
T2-MI interface
on
PLP number
1 to 20
Coding
bandwidth
1.7/5/6/7/8 MHz
MER
> 40 dB
13
modulation frequency response
< ±0.2 dB
shoulder attenuation
> 45 dB
PLP type
common, data type 1, data type 2
12
baseband mode
normal (NM), high efficiency (HEM)
ISSY
off, short, long
12
null packet deletion
on/off
12
FEC frame
normal (64k), short (16k)
code rate
1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 1/3
11, 12
,
2/5
11, 12
constellation
QPSK, 16QAM, 64QAM, 256QAM
rotation
on/off
time interleaver
settable
14
frame interval (I
jump
)
≥ 1
12
FFT size
1k, 2k, 4k, 8k, 16k and 32k COFDM
extended carrier mode
on/off
pilot pattern
PP1, PP2, PP3, PP4, PP5, PP6, PP7,
PP8
guard interval
1/4, 19/128, 1/8, 19/256, 1/16, 1/32, 1/128
10
Bias balancing cells and unoccupied cell filling between PLP cells not supported.
11
Features in line with T2 v1.3.1, including Annex I (T2-Lite).
12
With T2-MI interface switched on.
13
With internal test signals.
14
With T2-MI interface switched off.