Digital modulation systems
At least one I/Q baseband generator (R&S
®
BTC-B1 option) must be installed. If two I/Q baseband generators are installed
(R&S
®
BTC-B1 option and R&S
®
BTC-B2 option) and two signals of the same standard (e.g. DVB-T/DVB-H) are to be output
simultaneously, two corresponding software options must also be installed (in this case R&S
®
BTC-K501). If only one R&S
®
BTC-K501
is installed and DVB-T/DVB-H is selected in one I/Q baseband generator, the other I/Q baseband generator is disabled for
DVB-T/DVB-H. However, a software option is not tied to a specific I/Q baseband generator.
The specified data applies together with the parameters of the respective standard. The entire frequency range, the filter parameters
and symbol rates can be set by the user.
Terrestrial standards
DVB-T2 (R&S
®
BTC-K516 option)
in line with EN 302755 and TS 102773
v1.1.1, v1.2.1
10
and v1.3.1
11
, incl. Annex I
T2-Base single profile transmission
T2-Lite single profile transmission
v1.3.1
11
in line with Annex I
T2-MI (single PLP and multi PLP) or
MPEG-2 TS (single PLP only)
T2 specification check and logging
1 (single PLP) to 20 (multi PLP)
modulation frequency response
common, data type 1, data type 2
12
normal (NM), high efficiency (HEM)
normal (64k), short (16k)
1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 1/3
11, 12
,
2/5
11, 12
QPSK, 16QAM, 64QAM, 256QAM
1k, 2k, 4k, 8k, 16k and 32k COFDM
PP1, PP2, PP3, PP4, PP5, PP6, PP7,
PP8
1/4, 19/128, 1/8, 19/256, 1/16, 1/32, 1/128
Bias balancing cells and unoccupied cell filling between PLP cells not supported.
Features in line with T2 v1.3.1, including Annex I (T2-Lite).
With T2-MI interface switched on.
With internal test signals.
With T2-MI interface switched off.